EM系列

EM-series(ECO-shaker)

EM-series(ECO-shaker)

Vibration testing system is always developing.

IMV equips vibration testing system with “Intelligence”, and is always endeavoring to develop it to a good supporter for customers testing, from a simple testing equipment. We have now realized Eco technology.
ISM:Intelligent Shaker Manager
 
Full-scale automatic saving-energy driving

Complicated settings are not needed.

Electricity consumption may be controlled for some electro-dynamic shakers by hand, but it is quite difficult to optimize the consumption, depending on testing conditions and tested pieces. But our Eco-shaker can achieve efficiency optimization, depending on the test conditions.

Full-scale automatic saving-energy driving
You can confirm reduction of CO2 and electricity consumption at real-time.saving-energy driving

You can confirm the result of reduction of CO2 and electricity consumption at glance.

You can implement vibration simulation testing at the optimized power automatically in the same procedures as conventional ones, by combining it with IMV’s vibration controller “K2”. You can confirm real-time electricity consumption during testing, and so you can get figure of reduced electricity per each test.

You can confirm reduction of CO2 and electricity consumption at real-time.saving-energy driving
 
Improvement of operations atmosphere

You can expect improvement of operations atmosphere from low noise.

Noise to be arisen from vibration testing equipment may limit operator’s work and its location. Our Eco-shaker can control engine of blower at minimum and optimized speed, which can realize a cut of wasted consumption and low level of noise by reducing the speed depending on the testing conditions.

Improvement of operations atmosphere
Some figures calculated by comparing with conventional shaker with same force,

Comparison of electricity consumption with conventional shaker

The less output, the more saving-energy you can expect.
Comparison of electricity consumption with conventional shaker

Saving energy efficiency

Comparison of consumed electricity
Saving energy efficiency

Running cost

Efficiency of electricity bill reduction
Running cost
System Model Freq.Range Rated Force SINE

Max.Acc.

Max.Vel. Max.Disp. Power Requirements
Hz kN m/s2 m/s mm(p-p) kVA
EM2201 5~3,300 8.00 1250 2.2 51 16.4
EM2301 5~3,000 16.00 1250 2.2 51 26.0
EM2305 5~3,000 823 2.4 100 28.0
EM2401 5~2,600 24.00 1200 2.2 51 36.0
EM2405 5~2,400 769 2.4 100 37.0
EM2501 5~2,500 32.00 914 2.2 51 56.0
EM2505 5~2,200 35.00 622 2.4 100 58.0
EM2502 5~2,500 40.00 1142 2.2 51 64.0
 
 