SW-74SI
Seismic Monitoring System
SW-74SI
- SW-74S provides expanded Display functions and the greater variety of Alarm Signals, being connected with SW-72R which is usable even as a single unit. Furthermore, it is usable to retrofit the existing equipments because of its possibility to be hooked up with SW-94SL・SW-90K3 Detectors.

Features
- [Corresponds to the trend to use SI for Alarm]
- Use of SI which well correlates to the damage of the buildings or other structures on the Earthquakes is spreading in the Gas・Chemical Industries. SW-74S is the High-end Model which has the Alarm Function by SI in addition to te functions of SW-74.
- [Flexible Alarm setting-up is possible]
- SW-74 has independent each other 10 Alarm Outputs. Functions for
Alarm generation can be internally selected out of Acceleration・Seismic
intensity scale・SI individually. Alarm levels are also able to be
set-up optionally. Therefore, it can output Alarm Signals not only
of the fixed certain function by step but also of the mixed functions
as acceleration and SI
.
- [Addition of Functions (Comparison with SW-72R)]
-
- Alarm 7 steps (10 steps in total)
- FAULT Alarm
- Earthquake Occurrence Record Display
- Pickup Test
- [Interchangeability to Existing equipments]

Block Diagram

System Compsition

Outward Drawing

Specifications
Processing Unit(SW-74SI)
| MODEL | SW-74SI |
|---|---|
| Display Element |
STN monochrome LCD with Touch Switch (Back Light Color: Green / Orange / Red < No Replacement necessary> LCD life: 50,000 hrs mean (at normal temp. 25℃) |
| Earthquake Monitoring | Current Time |
| Earthquake Occurrence | Time of Earthquake Maximum Acceleration, Seismic intensity scale, Alarm action |
| Earthquake Hold | Reset Button (Alarm, Buzzer lump reset) |
| Various kind Setting | Trigger, Alarm, Date & Time |
| Maintenance | Pickup Test, Earthquake Records |
| Extra Alarms | Alarm Step: Upper 7 Steps (Alarm 4~10) Individual setting (Acceleration,/Seismic Scale/ SI / Options) Alarm Setting 0.1~999.9 (Gal / Seismic intensity scale / Kine) (Setting Interval: 0.1Gal, 00 for Alarm OFF) (Seismic Scale is to be set in Measured Seismic Scale) Alarm Relay Contact:1a (Photo MOS Relay) Independent COM 2 points (ALM1~5, ALM 6~10, one each) Contact Rating: 200V・0.65A (AC/DC, Peak value) |
| Alarm Reset | a. External Reset Terminals (All Steps are reset by closing No voltage a Contact) b. Automatic Reset by an Internal Timer 1~9999sec (Setting Interval 1sec, 0 for Automatic Reset OFF |
| FAULT Alarm | 1a / 1b Contact Switch over Contact Rating: 2A 30VDC (Max. Allowable Voltage / Current: 220VDC / 2A) |
| Alarm Buzzer | Alarm Setting 0.1~999.9 (Gal/Seismic Scale/Kine) (Setting Interval: 0.1Gal, 00 for Buzzer work OFF) (Seismic Scale is to be set in Measured Seismic Scale) |
| Serial 1 | For External Display / For Maintenance (Switch over) |
| Serial 2 | For Earthquake Data Printing (basing upon RS232C): MC2 |
| Uninterruptible Power Supply | Power Interruption Back up |
| Mounting | Wall Mount |
| Ambient Temperature | 0~+50℃ |
| Ambient Humidity | 10~85%RH |
| Power Supply | Single Phase (Option) |
| Power Consumption | 100VA or less (For DC24V:70W or less) |
| Outward Size | Refer to Outward Drawing |
| Painted Color | Panel : Close to Munsell 5GYB/0.5 Casing: Munsell N6.0 |
| Mass | Approx. 3Kg |
Option
- ■Printer

A printer prints Acceleration Amplitude, Seismic Scale and Alarm Signal generation Time, mounted on the panel. - ■Control Unit

A Control Unit makes reliability of the relay contact Output of the Alarm Signal to control or stop activation higher. An Alarm Signal is output when 2 units out of 3 generate such signals. - ■Annoane Machies

By an Announce Machine hooked up with the Seismometer, Earthquake information is announced.