Seismic Monitoring System

SW-74SI

SW-74S provides expanded Display functions and the greater variety of Alarm Signals, being connected with SW-72R which is usable even as a single unit. Furthermore, it is usable to retrofit the existing equipments because of its possibility to be hooked up with SW-94SL・SW-90K3 Detectors.

Seismic Monitoring System<SW-74SI> ハイエンドモデル

Features

[Corresponds to the trend to use SI for Alarm]
Use of SI which well correlates to the damage of the buildings or other structures on the Earthquakes is spreading in the Gas・Chemical Industries. SW-74S is the High-end Model which has the Alarm Function by SI in addition to te functions of SW-74.
[Flexible Alarm setting-up is possible]
SW-74 has independent each other 10 Alarm Outputs. Functions for Alarm generation can be internally selected out of Acceleration・Seismic intensity scale・SI individually. Alarm levels are also able to be set-up optionally. Therefore, it can output Alarm Signals not only of the fixed certain function by step but also of the mixed functions as acceleration and SI

.

 

[Addition of Functions (Comparison with SW-72R)]
  1. Alarm 7 steps (10 steps in total)
  2. FAULT Alarm
  3. Earthquake Occurrence Record Display
  4. Pickup Test
[Interchangeability to Existing equipments]

Block Diagram

System Compsition

Outward Drawing

Specifications

Processing Unit(SW-74SI)

MODEL SW-74SI
Display Element
STN monochrome LCD
with Touch Switch
(Back Light Color: Green / Orange / Red < No Replacement necessary>
LCD life: 50,000 hrs mean
(at normal temp. 25℃)
Earthquake Monitoring Current Time
Earthquake Occurrence Time of Earthquake
Maximum Acceleration,
Seismic intensity scale, Alarm action
Earthquake Hold Reset Button (Alarm, Buzzer lump reset)
Various kind Setting Trigger, Alarm, Date & Time
Maintenance Pickup Test, Earthquake Records
Extra Alarms Alarm Step: Upper 7 Steps
(Alarm 4~10)
Individual setting
(Acceleration,/Seismic Scale/
SI / Options)
Alarm Setting 0.1~999.9 (Gal / Seismic intensity scale / Kine)
(Setting Interval: 0.1Gal, 00 for Alarm OFF)
(Seismic Scale is to be set in
Measured Seismic Scale)
Alarm Relay Contact:1a
(Photo MOS Relay)
Independent COM 2 points
(ALM1~5, ALM 6~10, one each)
Contact Rating: 200V・0.65A
(AC/DC, Peak value)
Alarm Reset a. External Reset Terminals
(All Steps are reset by closing No voltage a Contact)
b. Automatic Reset by an Internal Timer
1~9999sec (Setting Interval 1sec, 0 for Automatic Reset OFF
FAULT Alarm 1a / 1b Contact Switch over
Contact Rating: 2A 30VDC
(Max. Allowable Voltage / Current: 220VDC / 2A)
Alarm Buzzer Alarm Setting 0.1~999.9 (Gal/Seismic Scale/Kine)
(Setting Interval: 0.1Gal, 00 for Buzzer work OFF)
(Seismic Scale is to be set in
Measured Seismic Scale)
Serial 1

For External Display / For Maintenance (Switch over)
For External Display (basing upon RS422):MC2
For Maintenance basing upon RS232C): MC1

Serial 2 For Earthquake Data Printing (basing upon RS232C): MC2
Uninterruptible Power Supply

Power Interruption Back up
10 minutes or longer (Recovery Stand- by time)
Charge time 48 hrs or shorter ) No Back-up for Optional DC24V Power Supply)

Mounting Wall Mount
Ambient Temperature 0~+50℃
Ambient Humidity 10~85%RH
Power Supply Single Phase
(Option)
Power Consumption 100VA or less
(For DC24V:70W or less)
Outward Size Refer to Outward Drawing
Painted Color Panel : Close to Munsell 5GYB/0.5
Casing: Munsell N6.0
Mass Approx. 3Kg

Option

■Printer
A printer prints Acceleration Amplitude, Seismic Scale and Alarm Signal generation Time, mounted on the panel.
■Control Unit
A Control Unit makes reliability of the relay contact Output of the Alarm Signal to control or stop activation higher. An Alarm Signal is output when 2 units out of 3 generate such signals.
■Annoane Machies
By an Announce Machine hooked up with the Seismometer, Earthquake information is announced.